Model | D-3.22/1-250-AN | D-4.5/1-250-AN | 4M5.5-9.5/250-AN | 4M5.5-14/250-AN | 4M5.5-17/250-AN |
Media | Pure natural gas | Pure natural gas | Pure natural gas | Pure natural gas | Pure natural gas |
Mode | D-type, water cooling, 4 stages | D-type, water cooling, 4 stages | D-type, water cooling, 4 stages | D-type, water cooling, 4 stages | D-type, water cooling, 4 stages |
Inlet Pressure | 0.1 Mpa | 0.1Mpa | 0.1Mpa | 0.1Mpa | 0.1Mpa |
Discharge Pressure | 25Mpa | 25Mpa | 25Mpa | 25Mpa | 25Mpa |
Inlet Temperature | ≤30℃ | ≤30℃ | ≤30℃ | ≤30℃ | ≤30℃ |
Discharge Temperature | ≤45℃ (after cooled) | ≤45℃ (after cooled) | ≤45℃ (after cooled) | ≤45℃ (after cooled) | ≤45℃ (after cooled) |
Supply Capacity | 380 Nm³/h | 533 Nm³/h | 1000 Nm³/h | 1500 Nm³/h | 1800 Nm³/h |
Rotation Speed | 740r/min | 740 r/min | 585r/min | 585r/min | 740r/min |
Transmission Mode | Direct couple | Direct couple | Direct couple | Direct couple | Direct couple |
Shaft Power | ≤88 KW | ≤130 KW | ≤215 KW | ≤320 KW | ≤385 KW |
Electric Motor | 90 KW, dllBT4, 380V, 50 Hz | 132 KW, dllBT4, 380V, 50 Hz | 250 KW, dllBT4, 380V, 50 Hz | 350 KW, dllBT4, 380V, 50 Hz | 400 KW, dllBT, 380V, 50 Hz |
Model | ZW-3.22/1-250-AN | ZW-5.0/1-250-AN | ZW-8.0/1-250-AN |
Media | Pure natural gas | Pure natural gas | Pure natural gas |
Mode | ZW-type, water cooling, 4 stages | ZW-type, water cooling, 4 stages | ZW-type, water cooling, 4 stages |
Inlet Pressure | 0.1Mpa | 0.1Mpa | 0.1Mpa |
Discharge Pressure | 25Mpa | 25Mpa | 25Mpa |
Inlet Temperature | =30℃ | =30℃ | =30℃ |
Discharge Temperature | =45℃(after cooled) | =45℃(after cooled) | =45℃(after cooled) |
Supply Capacity | 380 Nm³/h | 533 Nm³/h | 800 Nm³/h |
Rotation Speed | 740r/min | 740r/min | 740r/min |
Transmission Mode | Direct couple | Direct couple | Direct couple |
Shaft Power | =86.1 KW | =115 KW | =169 KW |
Electric Motor | 90 KW, dllBT4, 380V, 50 Hz | 132 KW, dllBT4, 380V, 50 Hz | 185 KW, dllBT4, 380V, 50 Hz |
Tag: Gas Driven Compressor | Gas Powered Air Compressor | Compressed Natural Gas Purificating System | Natural Gas Purification System
Tag: On-Grid Wind-Solar Hybrid Inverter | Grid-tie Wind Solar Hybrid Inverter | Gas Purificating Device | Compressed Natural Gas Purification Device